An R-454C Split ATW HP Investigation: Design Requirements To Match R-32 Performance

Experimental R454C ATW monoblock COP within 2% of R290, despite ~30% smaller heat exchanger. Modeling and optimizing R454C ATW split system (compressor, SLHX, sizing) to reach parity with R32 ATW split systems.

Themen

Klima & Lüftung & Wärmepumpen

Wann & Wo

calendar_month

Di., 13.10.2026 10:00 Uhr - 10:20 Uhr

location_on

Halle 7A / 7A-406

Session als iCal herunterladendownload_for_offline

Einzelheiten

  • Format:

    Vortrag

  • Sprache:

    Englisch

Session Beschreibung

An R454C air-to-water (ATW) monoblock heat pump was experimentally evaluated by an independent laboratory, benchmarked against a high-efficiency R290 ATW monoblock system. Test results show that the R454C system achieved COP values within 2% of the R290 baseline, despite using an outdoor heat exchanger with approximately 30% lower effective heat transfer area. 

Split ATW heat pumps remain relevant due to installation constraints and the need to avoid water–glycol secondary loops, which may be needed in monoblock systems to mitigate freezing. The present work aims to investigate the performance potential of an R454C-based split ATW system. A detailed system model is developed and validated using experimental data obtained from the R ...