This website uses cookies to make the content more user-friendly and effective. By using this website, you agree to the use of cookies. You can find additonal information about the use of cookies and the possibility of objecting to the use of cookies here.

16 - 18 October 2018 // Nuremberg, Germany

Posting print layout

What information should be shown in the print layout?

Create print layout
Exhibitors & Products Chillventa 2018
Zoom product LOGO_Differential Pressure Sensor 985 with a new IP65 enclosure

Differential Pressure Sensor 985 with a new IP65 enclosure

LOGO_Differential Pressure Sensor 985 with a new IP65 enclosure

Differential Pressure Sensor 985 with a new IP65 enclosure

Request information Request information

Contact us

Please enter your personal information and desired appointment. You can also leave us a message.

Your personal information

Your message for us

Desired appointment during the exhibition

* Compulsory fields you must fill in.

Information on data protection can be found here.

Send
Your message has been sent.

You do not have a registration yet? Register now and use all advantages of the Exhibitors and Products Database, the supporting programme and the TicketShop.

An error has occurred.

Differential Pressure Sensor 985 with a new IP65 enclosure

Differential pressure sensors for air allow for very reliable assessments of the status of a ventilation or air conditioning system in buildings. For example, they check if the filters are dirty, or if the fresh air ventilation runs properly. Through changes in air pressure, information about changes of the system parameters can be detected reliably. For building automation, air conditioning and clean-room systems, users thus have constant access to the most important operational data. To accommodate the manifold versions and requirements even in the difficult ambient conditions of these systems, a new differential pressure sensor now offers an enclosure in protection class IP65, as well as up to eight switchable measuring ranges.

In practice, this feature significantly facilitates work, if a user simply wants to install, correctly wire up and set the parameters of a pressure sensor in a few easy steps. A differential pressure sensor with adequate access at the open lid for these moves forms a good basic prerequisite for this purpose. Another useful feature is that the open lid is not separated from the device, but simply folds open and down during the installation works. If it becomes apparent during installation that the pressure conditions are not as expected, a suitable measuring range can be selected simply and quickly via the rotary selector switch without having to procure and use an alternative device. For this purpose, the new sensor by Beck Druckkontrolltechnik offers eight pressure measuring ranges that can be selected from the rotary selector switch and also various output signals. To guarantee clean, linear response for each range, the developers equipped the 985Q sensor with tried and tested automatic zero-point calibration. Drift caused by ageing, temperature or system-related influences can thus be reliably and permanently compensated.

The new 985 pressure sensor model range can capture differential pressures from 25 Pa to 100 kPa in various measuring range combinations. The three-wire output signal is selected through a jumper as 0...10 V or 4...20 mA. Likewise by jumper, users can select between a linear or a square-rooted signal. The latter is useful for measuring volume flows, for example. With a supply voltage of 24 VAC/VDC, current consumption with an LED display is a maximum of 230 mA. The IP65 enclosure measures 81 mm x 83 mm at a height of 41 mm. Two tube ports of 4 mm and 6 mm diameter allow for the use of tubes with different thicknesses for connection to the pressure port. The cable gland, with a cap nut screw connection of 15 AF, makes it possible to insert cables or stranded wires of up to 1.5 mm2 during on-site installation. The transmitters comply with EN 60770 and EN 61326, as well as RoHS according to 2011/65/EU.

Pressure Transmitter 981 for lowest pressures and liquid levels

LOGO_Pressure Transmitter 981 for lowest pressures and liquid levels

Pressure switch 901 Prescal®

LOGO_Pressure switch 901 Prescal®

Differential pressure switch 930.8x Climair®

LOGO_Differential pressure switch 930.8x Climair®

Self-zeroing differential pressure transmitters 984A and 985A

LOGO_Self-zeroing differential pressure transmitters 984A and 985A

Differential Pressure Sensor 985 with a new IP65 enclosure is assigned to following product groups:

You decided to attend the Chillventa? Get your tickets at the TicketShop



Chat

Do you have further Questions?

Chat with us.

top

The selected entry has been placed in your favourites!

If you register you can save your favourites permanently and access all entries even when underway – via laptop or tablet.

You can register an account here to save your settings in the Exhibitors and Products Database and as well as in the Supporting Programme.The registration is not for the TicketShop and ExhibitorShop.

Register now

Your advantages at a glance:

  • Advantage Save your favourites permanently. Use the instant access – mobile too, anytime and anywhere – incl. memo function.
  • Advantage The optional newsletter gives you regular up-to-date information about new exhibitors and products – matched to your interests.
  • Advantage Call up your favourites mobile too! Simply log in and access them at anytime.