Straight tube testing within seconds with WEH® Connector TW241
Straight tubes from 6.0 mm to 22.2 mm can be leak tested simply and easily using
the WEH® TW241 Quick Connector. Wherever straight tubes have to be pressure
tested or function tested, the WEH® TW241 is the right tool, being ideal for applications
in the refrigeration and air conditioning industry. Testing applications
include heat exchangers, pressure vessels, valves, transducers, compressors,
condensers, evaporation coils, air conditioners, heating systems and many more
RAC components. In the automotive industry the WEH® TW241 is used for radiator
testing.
The TW241 tightly seals the external diameter of straight tubes and bridges large
tube tolerances of up to ± 0.25 mm. Applications include vacuum testing and
pressure testing up to 70 bar. A pressure-assisted piston prevents disconnection
under pressure for additional safety. Operation is amazingly easy. Simply place
the WEH® Connector onto the straight tube, actuate the hand lever by 90° and
the pressure-tight connection is made and the test medium can be supplied. No
need for additional fixing.
The TW241 is ideal for water dunk, pressure decay and helium testing. Simplified
workflows, shorter operating times and increased productivity can be
achieved when using the WEH® TW241.
The extensive range of WEH® Products also includes WEH® Connectors for
sealing the interior diameters of tubes and a large variety of other connection
options, such as internal threads, external threads etc. Visit our homepage
www.weh.com and see for yourself. We have the right solution even for your
connection problem.