11 - 13 October 2016 // Nuremberg

Posting print layout

What information should be shown in the print layout?

Create print layout
Zoom product LOGO_Humidity and Temperature Transducer vith Heating Function from 95% r.H.

Humidity and Temperature Transducer vith Heating Function from 95% r.H.

LOGO_Humidity and Temperature Transducer vith Heating Function from 95% r.H.

Humidity and Temperature Transducer vith Heating Function from 95% r.H.

Request information Request information

Contact us

Please enter your personal information and desired appointment. You can also leave us a message.

Your personal information

Your message for us

Desired appointment during the exhibition

* Compulsory fields you must fill in.
Your message has been sent.

Would you like to use more facilities and advantages of the platform? Then please log in – or register here.

An error has occurred.

The humidity and temperature sensor with transducer measures the temperature and selectively the relative humidity, absolute humidity, air fuel ratio or dew point of the ambient air and transforms it to a linear output signal 0-10 V or 4-20 mA. The secondary measuring value is selectable from the 4 measurement categories % r.H., g/m³, g/kg, DP by a DIP switch. The humidity and temperature sensor is protected against contamination by a screwable sinter filter. In addition, the humidity measuring instrument has an integrated heating function for sensor protection in the high humidity range of 95...99% r.H. If the relative humidity exceeds the factory-preset threshold value for more than 10 minutes, this heating function is activated. Then the sensor will be temporally heated, thus dried respectively protected against condensation. During the heating and subsequent temperature compensation phase, the output signal is kept stable on the last measurement value before the protective function was activated. The humidity and temperature transducer can be adjusted locally for fine calibration by an offset controller.

Product specifications

Measurement range r.H.:

0...100% r.H.

Measurement range abs. humidity:

0...50 g/m³, 0...80 g/m³ (calculated) selectable by DIP switch

Measurement range air fuel ratio:

0...50 g/kg, 0...80 g/kg (calculated) selectable by DIP switch

Measurement range dew point:

-20 up to +50°C DP, -20 up to +80°C DP, 0 up to +50°C DP (calculated) selectable by DIP switch

Measurement range temp.:

-30...+70°C, -20...+80°C, 0...+50°C, 0...+100°C selectable by DIP switch


±3% r.H. (30%...70% r.H., else ±5% r.H. at 20°C), ±0,3 K (10...40°C, else ±0,5 K)

Temperature dependency:

< 0,02% r.H. / °C (voltage output), < 0,04% r.H. / °C (current version);

< 0,05°C / 10 K (voltage version), < 0,07°C / 10 K (current output)

Long term stability:



capacitive humidity sensor

Sensor protection:

screwable stainless steel sinter filter, condensation protection by heating function in the range of 95...99% r.H.

Flow rate:

< 2 m/s

Supply voltage at 0-10 V:

24 V AC/DC (±5%)

Supply voltage at 4-20 mA:

15...36 V DC (Ubmin = 15 V + RLast*0,02A)

Current consumption at 0-10 V:

typ. 10 mA

Current consumption at 4-20 mA:

max. 20 mA

Analogue output 0-10 V:

3-wire connection, load current <0,1 mA

Analogue output 4-20 mA:

2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub - 15 V) / 0,02 A

Electrical connection:

screw terminals max. 1,5 mm²


polyamide with snap closing screws, colour white like RAL 9010

Cable gland:

PG11 high-strength cable gland with strain relief


optional LCD-Display, to display the actual humidity and temperature


Protection tube: brass nickel-plated


Protection tube: Ø 16 x 40 mm

Protection type:


Protection class:


Working range r.H.:

0...98% r.H. in contaminant-free, non-condensing air

Working temperature:

Probe: -20...+80°C, Electronic: -30...+70°C

Storage temperature:



screw fastening


CE-conformity, EAC, RoHS


Motion/Brightness and Temperature Probe for Ceiling Mounting

LOGO_Bewegungs-/Helligkeits- und Temperaturfühler für die Deckenmontage

Mini Motion Probe with Infrared Sensor for Ceiling Mounting

LOGO_Mini-Bewegungsfühler mit Infrarot Sensor für die Deckenmontage

CO and Temperature Sensor with Measuring Range Changeover

LOGO_CO und Temperaturfühler mit Messbereichsumschaltung

Multifunctional Air Quality Sensor for CO2, Mixed Gas VOC, Humidity and Temperature with Measuring Range Changeover

LOGO_Multifunktionaler Luftqualitätsfühler für CO2, Mischgas VOC, Feuchte und Temperatur mit Messbereichsumschaltung

There are no entries in your notes.

Show notes


The selected entry has been placed in your notes!

If you register you can save your notes permanently and access all entries even when underway – via laptop or tablet.

You can register an account here to save your settings in the Exhibitors and Products Database and as well as in the Supporting Programme.The registration is not for the TicketShop and ExhibitorShop.

Register now

Your advantages at a glance:

  • Advantage Save your notes permanently. Use the instant access to exhibitors or products saved – mobile too, anytime and anywhere – incl. memo function.
  • Advantage The optional newsletter gives you regular up-to-date information about new exhibitors and products – matched to your interests.
  • Advantage Call up your notes mobile too! Simply log in and access them at anytime.